Materials Characterization


Differential Scanning Calorimetry – DSC

Equipment
Differential scanning calorimeter - Setaram, France, model DSC 131.
This equipment works in the temperature range between -150 °C and +550 °C, the heating and cooling speeds between 0,001 and 50 °C / min. The sign of heat flux ranges from -100 to +100 mW and the resolution is ± 0,2 μW.

Sample
Homogeneous solid or liquid samples with a minimum of 10 mg.

Price list
Note: 1) Figures do not include VAT.

Thermal Analysis

Universities and nonprofit organizations

Others

Termogram < 1 hour Above room temp.  7,50 € 15,00 €
With cryogenic 11,25 € 22,50 €
Termogram> 1 hour Above room temp. 15,00 € 30,00 €
With cryogenic 18,75 € 37,50 €

Method development

Contact the technician

Data Registry (Excel)

0,75 € / thermogram

1,50 € / thermogram

Thermogravimetric analysis – TGA

Equipment

Thermogravimetric equipment Setaram Labsys EVO.
This equipment works in the temperature range between ambient and 1600 ° C, the heating and cooling speeds of 0,01 to 100 ° C / min. Weighing precision of +/- 0,01%.

Sample
Homogeneous solid or liquid samples with a minimum of 10 mg.

Price list

Analysis

Universities and nonprofit organizations

Others

TGA/DSC

 

30,00 €

60,00 €

Method development

Contact the technician

X-ray Powder Difraction – XRPD

Equipment
Benchtop X-Ray Diffractometer RIGAKU, model MiniFlex II with:
Cu X-ray tube (30 KV/15 mA)
Scanning range: 3~ +145
° (2θ)
Scanning speed: 0,01~ +100
°/min (2θ)
Velocidade de varrimento: 0,01~ +100
°/min (2θ).
Minimum step width: 0,01
° (2θ)

Samples
Samples in dry powder form and homogeneous. The samples should be supplied in sufficient amount to cover 2 cm2 of the sample plate.

Price list

Diffractogram

Universities and nonprofit organizations

Others

Per sample

4,00 € / 15 min

5,50 € / 15 min

 

Note: 1) Figures do not include VAT.

Fourier Transform Infrared spectroscopy – FT-IR
Equipment

FT-IR Spectrometer, Perkin-Elmer – Spectrum 1000.

Samples

Liquids or dry solids.

Price list

FT-IR

Universities and nonprofit organizations

Others

Em KBr/KCl

25,00 €

40,00 €

Relatório

-

60,00 €

Note: 1) Figures do not include VAT. 

Mercury intrusion porosimetry – MIP

Equipment

Mercury porosimeter Micromeritics Autopore IV 9500.

Amostra
Dry solids. The block-shaped materials have to be adaptable to the 3 or 5 cm3 penetrometers. Samples cannot form amalgams with mercury. Attention: Destructive analysis.

Price list

MIP

Universities and nonprofit organizations

Others

Without sample preparation

50,00 €

100,00 €

Note: 1) Figures do not include VAT. 2) Contact the technician for sample preparation.

gas porosimetry-nitrogen – ASAP

Equipment
Gas porosimeter Micromeritics ASAP 2010 (Accelerated Surface Area and Porosimetry System).

Sample
Dry solids. Must be delivered at least 150 mg of sample.

Price list

Isotherm

Universities and nonprofit organizations

Others

Without sample preparation

50,00 €

100,00 €

 Note: 1) Figures do not include VAT. 2) Contact the technician for sample preparation.

 Analysis Request
The samples for analysis must be accompanied by the application form and forwarded to the technician of each equipment and/or laboratory.

Technique

Application Form

Contact

DSC

Download

cmr@fct.unl.pt

TGA

Download

FT-IR

Download

nuno.costa@fct.unl.pt

XRPD

Download

MIP

Download

ASAP

Download

The applicant should directly contact the responsible for the equipment to clarify all the issues concerning the analysis. The equipment is operated only by the technician in charge. If requested it is permitted direct contact with the equipment along with a brief technical/theoretical description accompanied by practical demonstration of operation.

Delivery and reception of samples

  1. Samples must be properly identified indelibly and must be delivered properly packed.

  2. The delivery of results will be made exclusively by e-mail in PDF format, sent simultaneously to the applicant and responsible.

  3. The remainder of the samples will be stored in the laboratory over a period of 15 working days after completion of the analysis, after which will be eliminated.