The mercury porosimetry is a technique that allows the analysis of a set of properties of solid structures by mercury intrusion pressure controlled. It is possible to obtain data on the distribution of pore size, diameter and total pore volume and density of the sample. Common applications are the ceramics and construction materials, catalysts, pharmaceuticals, filtration and adsorbent materials.
Mercury porosymeter - Micromeritics, Autopore, model IV 9500.

Dry solid samples (powders, blocks, membranes). The materials or block-shaped particles have to be adaptable to container 3 or 5 cc of the penetrometer. Samples can not form amalgams with mercury.
|
Mercury porosimetry |
Universities and nonprofit organizations |
Profit organizations |
|
Without sample preparation |
45 € |
60 € |
Note: 1) For samples that require some prior treatment, contact the coach. 2) The figures do not include VAT. 3) The urgency rate is three times the value of the table.
|
Number of samples |
Discount |
|
0 - 4 |
0% |
|
5 - 10 |
5% |
|
11 - 20 |
10% |
|
> 20 |
15% |
The analysis request should be filled and signed by the head of the institution that makes the request (Download the application form). Analyses are performed by order of submission of application in laboratory analysis. The results are given within 24 hours. In the case of samples for method development and in the case of large numbers of samples, the response time is agreed with the authority solicitor.
The equipment is operated solely by the technician in charge. If requested by the client it is allowed direct contact with the equipment which provides a brief technical/theoretical accompanied demonstration working practice.
Upon request of an analysis the client should contact the technician directly responsible for the equipment to clarify all issues that involve the analysis.
Download the application form
The application form should be sent to Eng. Nuno Costa:
nuno.costa@dq.fct.unl.pt
Laboratório de Análises
REQUIMTE - Rede de Química e Tecnologia
Departamento Química / Faculdade de Ciências e Tecnologia
Universidade Nova de Lisboa
2829-516 Caparica
Portugal
Tel: 351 212947805 (ext: 10993)
Fax:351 212948550
1 - Samples must be clearly identified, so that during manipulation does not erase the identification, and should be delivered well packaged.
2 - Delivery of results will be made by e-mail in PDF format, to be sent simultaneously to the applicant and responsible. In the case of complaints, they should be made within 15 working days.
3 - The remainder of the samples will be stored in the laboratory for 15 days after completion of the analysis, after which will be eliminated.